6.6 Deflector

General Item

6.6.1 Gradient of deflector and its adjustable range shall meet requirements of design technical document.

Check quantity:to check all.

Inspection method:to take actual measurement,to check installation quality records.

6.6.2 Amount of movement for movable deflector in horizontal direction shall meet requirements of design technical document.

Check quantity:to check all.

Inspection method:to check installation quality records.

6.6.3 Tolerance for deflector installation shall meet requirements in Table 6.6.3.

Check quantity:to check all.

Inspection method:see Table 6.6.3.

Table 6.6.3 Tolerance for deflector installation

img